eip: 5202
label: ERC-5202
title: Blueprint contract format
status: Final
type: Standards Track
category: ERC
created: 2022-06-23
requires: 170
official: https://eips.ethereum.org/EIPS/eip-5202
source: https://github.com/ethereum/ERCs/blob/master/ERCS/erc-5202.md
canonical: https://eips.huatuo.xyz/eip-5202/
lang: en
tldr: "A tiny bytecode header (0xFE71…) that marks a contract as a 'blueprint', meaning stored initcode for factories to copy, so it cannot be executed directly and tools can recognise it."
tags: [factory, bytecode, deployment, vyper, create2]
---

# ERC-5202: Blueprint contract format

> Define a bytecode container format for indexing and utilizing blueprint contracts

**TL;DR:** A tiny bytecode header (0xFE71…) that marks a contract as a 'blueprint', meaning stored initcode for factories to copy, so it cannot be executed directly and tools can recognise it.

## What problem does it solve?

Factory contracts that deploy many copies of a contract would bloat past the [EIP-170](/eip-170/) 24 KB code limit if they embedded the child's initcode. A common trick is to store the initcode on-chain as its own contract (a *blueprint*), then `EXTCODECOPY` it into memory and call `CREATE`/`CREATE2`.

But a blueprint is just code to the EVM, which creates two problems:

- **Safety:** anyone can call the blueprint and run the initcode as ordinary runtime code, triggering storage writes, external calls or even `SELFDESTRUCT`, which could break every factory depending on it.
- **Tooling:** indexers and explorers cannot reliably tell a blueprint from a normal contract.

## How it works

A blueprint's deployed bytecode starts with a preamble:

```text
0xFE 0x71 <version:6 bits | length-encoding:2 bits> [length bytes] [data] <initcode>
```

- `0xFE` is `INVALID`, so a direct call halts immediately and the initcode never runs as runtime code.
- `0x71` is a magic byte (the last byte of `keccak256("blueprint")`) that distinguishes blueprints from other code starting with `0xFE`.
- The third byte holds a 6-bit **version** (currently 0) and 2 **length-encoding bits** `n` (0, 1 or 2). If `n > 0`, the next `n` bytes give, big-endian, the length of an optional **data** section that indexers can skip. `0b11` is reserved for a future multi-byte version.
- Everything after that is the initcode, which MUST be at least one byte. Its length is not stored; use `EXTCODESIZE`.

Examples from the spec: `0xFE710000` is a blueprint whose initcode is `STOP`, and `0xFE71|01|07|FFFFFFFFFFFFFF|00` adds a 7-byte data section.

The spec notes it may be obsoleted if EOF ([EIP-3540](/eip-3540/)) ever adds a native initcode section.

## Sample code

Parsing a blueprint off-chain (TypeScript, ethers v6):

```ts
import { JsonRpcProvider, getBytes } from "ethers";

async function readBlueprint(provider: JsonRpcProvider, addr: string) {
  const code = getBytes(await provider.getCode(addr));
  if (code[0] !== 0xfe || code[1] !== 0x71) throw new Error("not a blueprint");
  const version = code[2] >> 2;
  const nLen = code[2] & 0b11;
  if (nLen === 3) throw new Error("reserved length encoding");
  let dataLen = 0;
  for (let i = 0; i < nLen; i++) dataLen = (dataLen << 8) | code[3 + i];
  const start = 3 + nLen;
  const data = nLen ? code.slice(start, start + dataLen) : null;
  const initcode = code.slice(start + dataLen);
  if (initcode.length === 0) throw new Error("empty initcode");
  return { version, data, initcode };
}
```

## Things to know

- Status: **Final**. Vyper's `create_from_blueprint` builtin is built around blueprint contracts of this kind.
- Factories must skip the preamble when copying: `EXTCODECOPY` from offset `3 + n + dataLen`, not 0.
- A blueprint is not a proxy. Each deployment from it is an independent contract, unlike [ERC-1167](/eip-1167/) minimal proxies, which delegate to shared logic.
- Pre-existing contracts could start with `0xFE71` by chance; the spec judged this low risk and says that, as of July 2022, none on mainnet did.


---